A dark region beside dense metal in an X-ray CT reconstruction may need further interpretation before it is classified as a defect. Preserve the raw acquisition and reconstruction context. A screenshot alone can hide the information needed to distinguish a physical feature from an imaging artifact.

Identify the actual inspection question

Mark the suspected joint, interface or void and explain the relevant failure observation. Provide the analyst with the assembly materials and approximate geometry. Dense neighboring features can influence the inspection even when they are not the target.

Nikon’s industrial CT information describes reconstruction and correction approaches for imaging artifacts. The availability of such methods shows that reconstructed contrast needs technical interpretation; it does not mean a correction automatically removes every ambiguity in a particular board.

Keep the acquisition context

Information Reason to retain it
Sample orientation Connects projections and dense features to the target
Acquisition method Defines the represented imaging conditions
Reconstruction settings Identifies how the volume was produced
Corrections applied Makes processed and original views distinguishable
Resolution assessment Bounds the size and contrast of interpretable features

Ask the qualified analyst to explain whether the suspected feature is supported across neighboring slices and appropriate views. Avoid changing display settings solely until the image resembles the expected failure.

Test the competing explanations

Where justified, compare an alternative acquisition, reconstruction or specimen orientation. Define what change would help distinguish the artifact hypothesis from a physical discontinuity. Keep the original result rather than replacing it with only the most persuasive-looking image.

For example, a streak aligned with several dense objects deserves a different follow-up from a discontinuity consistently located at the same joint interface in multiple views. The analyst should explain the evidence for the chosen interpretation.

If destructive confirmation is needed, plan it using the CT location map. Preserve enough material to reach the suspected feature and keep the CT-to-section registration explicit.

Retain an image of the complete assembly beside the detailed view. It helps reviewers identify dense structures outside the cropped region that may be relevant to the analyst’s explanation of the reconstructed feature.

Report confidence and limitations

Separate an observed contrast feature from a confirmed crack, void or separation. State what could not be resolved and why. An inconclusive scan should not be converted into either an assumed pass or a categorical defect call.

When comparing lots, use equivalent methods or explain the change in capability. Better imaging can reveal a previously unresolved feature without showing that manufacturing has become worse.

The CT slice-plane guide keeps the viewed plane tied to the joint, while section targeting supports physical confirmation.

Move from reading to a build-ready project

Use the fabrication and assembly checklists to prepare drawings, production files and test requirements.

Open the DFM checklist