A thermocouple reports the temperature established at its sensing junction, which may differ from the package surface if attachment and wire routing are poorly controlled. A label reading ‘case temperature’ is not enough to explain the physical measurement. Document how the junction contacts the package and how the installation affects heat flow.
Define the intended temperature
Decide whether the test needs the top package surface, a lead, a board location, a heat sink, or local air. These are different measurement points. Do not apply a thermal calculation that requires one of them to a sensor installed at another.
Texas Instruments’ semiconductor package thermal metrics guidance describes case-temperature measurement and warns that the thermocouple itself can conduct heat away. Its discussion of wire size, attachment, and routing shows why sensor installation belongs in the test method. Use the package-specific guidance when it provides a defined procedure.
Make the installation reproducible
- Photograph the intended junction location before attachment.
- Record thermocouple type, wire size, attachment material, and contact arrangement.
- Route and secure the wires consistently without mechanically loading the component.
- Verify that the sensor remains attached throughout the test.
- Record any enclosure or heat-sink modification needed for access.
A large adhesive deposit can change local heat transfer, while an inadequately attached bead may respond mainly to nearby air. Neither problem is corrected by using a more precise temperature logger. Select an attachment method appropriate to the surface, temperature, and test purpose.
Compare under the actual operating conditions
Record input voltage, workload, ambient location, airflow, board orientation, and stabilization criterion. If a lid must remain open to route wires, explain how that differs from the product’s normal thermal boundary conditions. Where practical, arrange access that preserves the intended enclosure and cooling behavior.
For a comparison between two board revisions, use the same sensor location and attachment method. An apparent improvement caused by moving the bead toward a cooler package edge is not evidence that the revised design dissipates heat better. Repeat an installation when the measurement is close enough to a decision limit that attachment variation could alter the conclusion.
Keep raw time histories and note whether the reported result is a steady value or a transient peak. Distinguish directly measured surface temperature from an estimated junction temperature and identify the assumptions behind any estimate. The useful deliverable is a traceable thermal observation of a defined location under defined conditions, rather than a single number detached from the sensor that produced it.