“Update once per second” is a communication requirement unless it also defines how the measurement is acquired. A product may sample quickly, filter locally, and report slowly. It may also wake once per second and miss everything between readings. Engineering a sensor product requires those behaviors to be specified separately.

Describe the shortest event that matters

For a vibration indicator, write down the shortest event duration, its expected frequency content, and the decision the product must make. Detecting the existence of movement needs different evidence from estimating peak amplitude or analyzing a waveform. A slowly reported maximum can be useful only if the acquisition path actually observed the event and did not clip it.

Consider an illustrative ten-millisecond event and a sensor read every hundred milliseconds. Depending on phase, that event can occur completely between reads. This timing observation does not select an adequate waveform sampling rate; bandwidth and anti-alias filtering still need separate analysis. It does explain why a display refresh setting cannot establish event coverage.

Map all four rates

Rate or interval Engineering purpose
Sensor conversion rate Determines when new physical observations are produced.
Filter response Changes noise, bandwidth, and reaction to short events.
Host service interval Determines when stored observations are retrieved.
Reporting interval Determines when a user or remote system receives a summary.

The ADXL362 manufacturer documentation is an example of a sensor with configurable acquisition behavior and an internal FIFO. Such features allow host activity and measurement activity to differ. They do not remove the need to verify the chosen configuration against the event.

Check delays as well as rates

A digital filter may suppress a short pulse or delay a threshold crossing even when its nominal output rate looks adequate. Measure step and pulse response with the final configuration. The output-rate and aliasing review explains why rate changes must be evaluated together with filtering. Retain configuration identifiers in test records so two results are not compared under different bandwidths accidentally.

Next, calculate the available buffer time from usable capacity and incoming data rate. Include interrupt latency, competing firmware work, bus transactions, and retry behavior. Use the FIFO service budget to check the worst credible delay, not only the average processor load observed at the bench.

Make the acceptance test phase-aware

Apply the same event at different offsets relative to the acquisition and reporting clocks. Test near the threshold and at both the shortest and longest intended duration. Verify the event timestamp, not just whether a later packet contains an alarm. If events can merge, document the merge rule and its effect on counts. A successful design states its observable event envelope and reports data gaps outside it, with supporting interface and measurement checks linked from the engineering resources.

Move from reading to a build-ready project

Use the fabrication and assembly checklists to prepare drawings, production files and test requirements.

Open the DFM checklist