A detector calibrated with a continuous sine wave may report a different value for a modulated signal with the same average power. The result depends on the detector architecture, waveform peaks, operating range, and output filtering. Identify what the circuit measures before assigning a power label to its voltage.
Read the response definition
Determine whether the device responds to RMS, envelope, peak, logarithmic amplitude, or another specified quantity. The Analog Devices ADL5501 data sheet describes an RMS responding detector and discusses performance for signals with differing crest factors. Even a suitable detector must operate within its documented frequency, amplitude, and waveform conditions.
Do not assume that every device with a logarithmic output provides identical response to changing modulation. Read the characterization relevant to the intended waveform and note any correction procedure.
Budget peaks and average separately
Record average power and peak to average ratio at the detector input. A waveform with the same average power as the calibration tone can have much larger instantaneous peaks. Those peaks may approach an input limit even while the average lies near the center of the nominal detection range.
Include the coupler, attenuator, and matching network that feeds the detector. Their frequency response and loss determine the actual stimulus. Verify the reference plane used by the calibration. Keep any coupler frequency correction associated with the corresponding detector calibration data.
Match output timing to the question
Review the detector’s response time and any external filtering. A slow output may be appropriate for mean power but unable to follow a short burst. Conversely, a fast output can require deliberate digital averaging to produce a stable reported value.
Compare the observation interval with burst duration and repetition. State whether the desired number is average power over the entire interval or power during the active burst. These quantities can differ substantially without either instrument being wrong.
Validate with representative waveforms
Compare detector output against a suitable calibrated reference measurement using both the calibration waveform and the intended modulation. Sweep the useful power and frequency range. Include startup and short bursts if they are part of the application.
Save waveform definition, reference power, detector configuration, output filter, and sampling method with the calibration data. If different waveforms require different corrections, make the selection explicit in software and documentation. A trustworthy power reading is tied to a verified response model; a voltage that moves monotonically with RF level is only the beginning of that verification.