An I2C target can work with one controller and fail with another even when both use the same nominal bus speed. One possible difference is clock stretching. Verify that the entire controller path can recognize and tolerate the target’s documented behavior before treating the problem as an address or pull-up issue.
Identify the target’s requirement
NXP’s I2C-bus specification, UM10204 describes clock stretching as holding SCL low to pause a transaction and identifies it as an optional feature. Therefore, support should be checked for the actual devices and operating mode rather than assumed from the I2C name alone.
Read the target’s documentation to determine whether it stretches, during which operations and under what timing conditions. Record differences between normal conversion, initialization and special commands. A target that rarely stretches may pass short tests while failing during the one operation omitted from the test sequence.
Follow the clock path
Check controller peripheral support, driver configuration, timeout handling and any USB bridge, bus buffer or translator in the route. Confirm that software observes the actual SCL state where required rather than assuming that a command to release the clock has already produced a high level.
Distinguish a legitimate stretch interval from slow rising edges or a line held low by a fault. Use analog waveforms alongside a protocol decoder when the distinction is unclear. A decoded timeout message by itself does not identify which device prevented progress.
Make timeout behavior deliberate
Choose timeout limits from the target’s documented behavior and the system’s response requirement. Avoid simply increasing a timeout until a failing test becomes green. An indefinitely blocked task can be unacceptable even when waiting longer helps one transaction succeed.
Record what happens after a timeout: whether the transaction is abandoned, retried or followed by a controlled recovery. Keep repeated writes and commands with side effects in mind. Reissuing a command because the response was delayed is not always equivalent to completing the original command once.
Verify the least convenient operation
Exercise commands and operating conditions that invoke the longest relevant stretch, then observe SCL, SDA and controller status. Include processor load and the actual bridge or buffer hardware. Testing through a different laboratory adapter cannot prove the production controller behaves identically.
The resulting compatibility record should identify the target behavior, the controller’s supported response and the bounded timeout policy. If any element lacks documented support, resolve that limitation before release. This prevents a nominally matching I2C speed from hiding a handshake requirement that the selected controller path cannot meet.