A buck converter regulates the voltage represented by its feedback network. That may differ from the voltage at a distant load because copper, vias and connectors carry current and develop voltage drops. Decide where regulation is required before routing the feedback trace, and follow the selected controller’s sensing arrangement.
Define the regulated location
Identify the load or local output node whose voltage must meet the requirement. Trace the power and return paths between that node and the converter. Include current-sharing paths that change with operating mode. A positive-side drop and a return-side drop can both affect the voltage actually seen by the load.
Texas Instruments’ discussion of remote buck sensing explains how sensing at the load can address PCB voltage drop in suitable implementations. Remote sensing must be supported and applied according to the controller’s guidance; moving one trace is not automatically a valid modification to every regulator.
Quantify the distribution drop
As an illustrative DC example, 2 A through a combined 25 milliohms of supply and return resistance creates 50 millivolts of difference. Compare that with the load’s voltage tolerance and the converter’s own regulation error. Use relevant operating temperature and current distribution for the actual calculation.
Check what happens at other loads on the same rail. Compensating a distant drop can raise the voltage near the converter. The entire rail must remain within its allowed range, including light-load conditions and disconnected remote loads where those states are supported.
Keep feedback routing electrically quiet
Review the divider placement and feedback reference according to the device’s layout recommendations. Avoid coupling from switching nodes, gate-drive paths and other high-slew-rate conductors. A trace can have negligible DC resistance and still collect noise that perturbs the control loop.
Distinguish a sense connection from a power-current path in the layout. Ensure copper pours and vias do not accidentally force substantial load current through a segment intended only to represent voltage. For differential sensing, review both traces and their reference relationship.
Validate at both ends of the rail
Measure voltage at the converter output and at the specified load location during static and transient conditions. Use an appropriate probing method and document ground references. Compare load-step response with the control-loop requirements after any sensing change.
Include startup, shutdown and relevant connection faults in the supported validation plan. Preserve the chosen sense point, distribution-drop estimate and measured response with the PCB review. A later connector, plane or load-placement change can alter the regulation problem without changing the feedback resistor values.